NetBotz Spot Fluid Sensor - Fluid detector - 4.5 m - for P/N: AR106SH4, AR106SH6, AR106V, AR106VI, AR109SH4, AR109SH6, AR112SH4, AR112SH6, AR3106SP

Category: Computer Coolers
Code: NBES0301
Warranty: 24 Months
Manufacturer (by 1WorldSync)
 
Unknown
IMBE-PE02
 
Unknown
NL326
 
Unknown
TDBE
 
Unknown
ALSNL1
 
Unknown
ALSBE
 
Unknown
DE168
 
Unknown
COPBE
 
Unknown
DK773
 
24 Months
For illustrative purpose only
Stock Qty Est. Delivery Price
VAT
IMBE-PE02 1 20/11/2024 unknown 112.15
NL326 1 19/11/2024 unknown 112.68
TDBE 1 19/11/2024 unknown 116.09
ALSNL1 5 21/11/2024 unknown 116.59
ALSBE 5 20/11/2024 unknown 121.64
DE168 13 20/11/2024 unknown 129.06
COPBE 0 unknown 134.36
DK773  13  13/12/2024 unknown 171.64

Marketing description

The NetBotz Spot Fluid Sensor uses electronic circuits to detect the presence of fluid. If the sensor contacts are shorted, the fluid detection circuits will not work. Shorting can occur when the sensor is placed on a metal surface, or on some materials, such as cement flooring (particularly cement that is wet), that may be conductive and grounded. Place the Spot Fluid Sensor on the provided insulator sheet to avoid shorting the contacts.
While your Spot Fluid Sensor is fluid-resistant, it is intended for leak detection only and is not designed to be immersed for extended periods of time. Use only plain tap water to clean your Spot Fluid Sensor. Do not use soap or detergents of any kind. In addition, the RJ-45 coupling should not be an area where water will collect or condensation may form, as this may corrode the coupling.

Key selling points

  • Using the insulator sheet on a conductive surface
  • Configuring the Spot Fluid Sensor
  • Caring for and cleaning your sensor

Product features

  • Using the insulator sheet on a conductive surface
    The NetBotz Spot Fluid Sensor uses electronic circuits to detect the presence of fluid. If the sensor contacts are shorted, the fluid detection circuits will not work. Shorting can occur when the sensor is placed on a metal surface, or on some materials, such as cement flooring (particularly cement that is wet), that may be conductive and grounded. Place the Spot Fluid Sensor on the provided insulator sheet to avoid shorting the contacts.
  • Configuring the Spot Fluid Sensor
    Use the advanced view and the external sensors task to configure the NetBotz appliance to use the NetBotz Spot Fluid Sensor. The Spot Fluid Sensor is a normally open dry contact sensor. Once you have configured your appliance, an additional sensor will appear in the Sensor Readings pane. Use the Dry Contact task to configure the settings for the NetBotz Spot Fluid Sensor. See the NetBotz Appliance User's Guide for more information about the Advanced View and the External Sensor task.
  • Caring for and cleaning your sensor
    While your Spot Fluid Sensor is fluid-resistant, it is intended for leak detection only and is not designed to be immersed for extended periods of time. Use only plain tap water to clean your Spot Fluid Sensor. Do not use soap or detergents of any kind. In addition, the RJ-45 coupling should not be an area where water will collect or condensation may form, as this may corrode the coupling.

Documents

 User manual

Product Description
NetBotz Spot Fluid Sensor - fluid detector
Product Type
Fluid detector
Length
4.5 m
Designed For
P/N: AR106SH4, AR106SH6, AR106V, AR106VI, AR109SH4, AR109SH6, AR112SH4, AR112SH6, AR3003, AR3003SP, AR3006, AR3006SP, AR3103, AR3103SP, AR3106, AR3106SP, AR3357X674, AR9300SP, AR9300SP-R, AR9307SP, AR9307SP-R, NBRK0250, NBRK0451/50, NBRK0570, NBRK0750, NBWL0355A, NBWL0356A, NBWL0455A, SMT1500RM2UC
Product Type
Fluid detector
Length
4.5 m
Connector Provided
1 x RJ-45 male
Designed For
P/N: AR106SH4, AR106SH6, AR106V, AR106VI, AR109SH4, AR109SH6, AR112SH4, AR112SH6, AR3003, AR3003SP, AR3006, AR3006SP, AR3103, AR3103SP, AR3106, AR3106SP, AR3357X674, AR9300SP, AR9300SP-R, AR9307SP, AR9307SP-R, NBRK0250, NBRK0451/50, NBRK0551, NBRK0570, NBRK0750, NBWL0355, NBWL0355A, NBWL0356A, NBWL0455A, SMC1500-2U, SMT1500RM2UC