NetBotz Spot Fluid Sensor - Fluid detector - 4.5 m - for P/N: AR106SH4, AR106SH6, AR106V, AR106VI, AR109SH4, AR109SH6, AR112SH4, AR112SH6, AR3106SP

Код NBES0301
Марка Schneider Electric
Гаранция Непознат
Само с пояснителна цел
Наличност Количество Приблизителна доставка Цена
IMHK 0 ~4 седмици 802,62

Маркетинг описание

The NetBotz Spot Fluid Sensor uses electronic circuits to detect the presence of fluid. If the sensor contacts are shorted, the fluid detection circuits will not work. Shorting can occur when the sensor is placed on a metal surface, or on some materials, such as cement flooring (particularly cement that is wet), that may be conductive and grounded. Place the Spot Fluid Sensor on the provided insulator sheet to avoid shorting the contacts.
While your Spot Fluid Sensor is fluid-resistant, it is intended for leak detection only and is not designed to be immersed for extended periods of time. Use only plain tap water to clean your Spot Fluid Sensor. Do not use soap or detergents of any kind. In addition, the RJ-45 coupling should not be an area where water will collect or condensation may form, as this may corrode the coupling.

Ключови точки за продажби

  • Using the insulator sheet on a conductive surface
  • Configuring the Spot Fluid Sensor
  • Caring for and cleaning your sensor

Характеристики на продукта

  • Using the insulator sheet on a conductive surface
    The NetBotz Spot Fluid Sensor uses electronic circuits to detect the presence of fluid. If the sensor contacts are shorted, the fluid detection circuits will not work. Shorting can occur when the sensor is placed on a metal surface, or on some materials, such as cement flooring (particularly cement that is wet), that may be conductive and grounded. Place the Spot Fluid Sensor on the provided insulator sheet to avoid shorting the contacts.
  • Configuring the Spot Fluid Sensor
    Use the advanced view and the external sensors task to configure the NetBotz appliance to use the NetBotz Spot Fluid Sensor. The Spot Fluid Sensor is a normally open dry contact sensor. Once you have configured your appliance, an additional sensor will appear in the Sensor Readings pane. Use the Dry Contact task to configure the settings for the NetBotz Spot Fluid Sensor. See the NetBotz Appliance User's Guide for more information about the Advanced View and the External Sensor task.
  • Caring for and cleaning your sensor
    While your Spot Fluid Sensor is fluid-resistant, it is intended for leak detection only and is not designed to be immersed for extended periods of time. Use only plain tap water to clean your Spot Fluid Sensor. Do not use soap or detergents of any kind. In addition, the RJ-45 coupling should not be an area where water will collect or condensation may form, as this may corrode the coupling.

Product Description
NetBotz Spot Fluid Sensor - fluid detector
Product Type
Fluid detector
Length
4.5 m
Designed For
P/N: AR106SH4, AR106SH6, AR106V, AR106VI, AR109SH4, AR109SH6, AR112SH4, AR112SH6, AR3003, AR3003SP, AR3006, AR3006SP, AR3103, AR3103SP, AR3106, AR3106SP, AR3357X674, AR9300SP, AR9300SP-R, AR9307SP, AR9307SP-R, NBRK0250, NBRK0451/50, NBRK0570, NBRK0750, NBWL0355A, NBWL0356A, NBWL0455A, SMT1500RM2UC
Product Type
Fluid detector
Length
4.5 m
Connector Provided
1 x RJ-45 male
Designed For
P/N: AR106SH4, AR106SH6, AR106V, AR106VI, AR109SH4, AR109SH6, AR112SH4, AR112SH6, AR3003, AR3003SP, AR3006, AR3006SP, AR3103, AR3103SP, AR3106, AR3106SP, AR3357X674, AR9300SP, AR9300SP-R, AR9307SP, AR9307SP-R, NBRK0250, NBRK0451/50, NBRK0551, NBRK0570, NBRK0750, NBWL0355, NBWL0355A, NBWL0356A, NBWL0455A, SMC1500-2U, SMT1500RM2UC